It’s the first time I own a dryer. When I poured out the water it has collected (a few liters per run) I quickly tested the EC and pH and found out, that it is almost identical to the one made by my reverse osmosis filter!
No wonder, since the dryer is basically just a big distillation machine.

Thats super neat. It will save me a lot of work filtering tap water.

I will collect it from now on and use it for watering my plants.

Why does it matter?

Plants really don’t like tap water. Even in a country like mine, where no chlorine/ fluoride/ whatever is added, the dissolved minerals cause trouble. They will build up over time and make nutrients unavailable, even if you adjust the pH.

The buildup and nutrient lockout will harm the plants a lot in the long term, and you will have way more trouble checking and correcting EC and pH.

  • Günther Unlustig 🍄@slrpnk.netOPM
    link
    fedilink
    English
    arrow-up
    5
    arrow-down
    1
    ·
    2 days ago

    Distilling separates fractions in the liquid by boiling point.

    True, but it also includes the step with the condensation collumn and collection of the condensate. Boiling isn’t linear, it can also turn into vapor at room temperature, especially with air movement.

    Distilled water will have zero conductivity,

    Not exactly. Gases, particularly CO2, can dissolve in it, and form carbonic acid for example. That’s why it doesn’t have a pH of 7, but 5-6ish.

    As an aside because I am insufferable

    Dude, stop saying that. That’s rude to yourself! 🤗

    You’re just telling me concerns you have, not more. That’s great. I like discussions and discourse, this is why we’re here! And this is how people get smarter.

    used interchangeably because TDS is a massive pain to test at home. If you are always measuring the same thing, it’s fine to use conductivity as a surrogate, but you can’t compare the conductivity of sugar water to salt water and assume you have a good idea of the TDS.

    AFAIK the TDS is the TDS700 to be precise, which is for measuring nitrogen or something. It’s a really shitty and inaccurate unit, which is why the EC is the preferred measurement for many hydro growers, including me.

    What you’re saying is that the dissolved/ dispersed things aren’t detectable by condictivity, did I understand that correctly?

    If so, then there have to be visible particles. I will do further experiments and boil some off to see if there are residues forming.

    I won’t venture to comment about its use on plants but to folks asking about drinking it in the comments, please don’t. Even if it was distilled it’s hanging out in an environment full of airborne life and wouldn’t remain sterile for long.

    I personally just treat it just as rainwater. Never ever would I drink something of it, and in case of rainwater, there’s some visible debris floating around. In the condensate maybe too, we’ll see!

    (Credentials: chemistry profession)

    • Cort@lemmy.world
      link
      fedilink
      arrow-up
      5
      ·
      2 days ago

      I’d be concerned about lint or micro plastic nylon (etc.) fibers in there. I doubt the lint filter is collecting 100% of the fibers before the warm moist air gets blown over the evaporator/condenser coils where condensate is collected.

      • Günther Unlustig 🍄@slrpnk.netOPM
        link
        fedilink
        English
        arrow-up
        3
        ·
        2 days ago

        Yep, seems like it. I just looked at it closer in a glass beaker and saw lots of floaters around.

        I still think most of it is cotton fibres, and even if it’s microplastic, it is mostly inert and plants don’t care much about it. I flush out my substrate every few months anyway, and not use it for food contact plants.

    • Arcanepotato@crazypeople.online
      link
      fedilink
      English
      arrow-up
      2
      ·
      2 days ago

      Not exactly. Gases, particularly CO2, can dissolve in it, and form carbonic acid for example. That’s why it doesn’t have a pH of 7, but 5-6ish.

      Fair - most of my distillation experience is not on water so I goofed in this fact (oversimplified)

      AFAIK the TDS is the TDS700 to be precise, which is for measuring nitrogen or something. It’s a really shitty and inaccurate unit, which is why the EC is the preferred measurement for many hydro growers, including me.

      I think I’m missing some jargon.

      TDS700? This is the method I am familiar with for TDS: https://edgeanalytical.com/wp-content/uploads/Waste_SM2540.pdf

      Measuring nitrogen is a massive fucking pain with gross reagents but I suspect the nitrogen I work with is a lot different than nutrient mixes in hydro lol. Anything that needs a digestion step gets shipped to a Real lab.

      I guess using conductivity for nitrogen is more about assuming the nutrient is “pure” but in different concentrations so you are just trying to see how dilute or concentrated it is based on the conductivity. I suppose that means it’s it’s a surrogate measurement not a direct measurement, which is why EC would be better than an actual TDS for that.

      What you’re saying is that the dissolved/ dispersed things aren’t detectable by condictivity, did I understand that correctly?

      If so, then there have to be visible particles. I will do further experiments and boil some off to see if there are residues forming.

      Yes, but specifically that there are dissolved things that are not detectable by conductivity. No conductivity doesn’t mean the solids must be non-dissolved. Not all things dissolve by breaking into ions. And not all ions give the same conductivity.

      I misunderstood what you use the conductivity for - if it’s to tell the strength of a known composition of unknown dilution, that’s a pretty straight forward correlation.

      Take for example the use of EC for TDS in drinking water, as described here: https://health.canada.ca/publications/healthy-living-vie-saine/water-dissolved-solids-matieres-dissoutes-eau/alt/water-dissolved-solids-matieres-dissoutes-eau-eng.pdf

      The method most commonly used for the analysis of TDS in water supplies is the measurement of specific conductivity with a conductivity probe that detects the presence of ions in water. Conductivity measurements are converted to TDS values by a factor that varies with the type of water.(18,19)